HEPA Filter Large Room Air Purifier Air Volume 5000m3 / H
Contact Person : Seline Zheng
Phone Number : +86 573 8188 3938
Minimum Order Quantity : | negotiable | Price : | negotiable |
---|---|---|---|
Packaging Details : | Ekeair Carton boxes with wooden cases | Delivery Time : | 30 days |
Payment Terms : | L/C, T/T | Supply Ability : | 100 sets monthly |
Place of Origin: | China | Brand Name: | Ekeair |
---|---|---|---|
Certification: | CE | Model Number: | MKJ4000 |
Detail Information |
|||
Product Name: | Continuous Dynamic Sterilization Of MKJ4000 Series Mobile Air Sterilization Station | MKJ4000-S1 Purification Area: | ≤50m3/100m3 |
---|---|---|---|
MKJ4000-S2 Purification Area: | ≤40/100/200 M3 | MKJ4000-S4 Purification Area: | ≤100m3/200m3/500m3 |
Air Capacity: | 1000 M3/h;2000 M3/h;5000 M3/h | QC Profile: | CE LVD EMC |
Mesh Type: | HEPA Filter Net/ Molecular Sieve/ UVC Lights | Voltage: | 220V |
High Light: | 1000m3/h Clean Station Air Purifier,HEPA Clean Station Air Purifier,HEPA Filter Net Air Sterilization |
Product Description
Continuous Dynamic Sterilization Of MKJ4000 Series Mobile Air Sterilization Station
OBM services:
Ekeair ® Mobile air sterilization station
High-efficiency Particulate Air Filter (HEPA) is one of the most popular technologies used in air purification. Standard HEPA filter can absorb 99.7% size of 0.3 microns of suspended particulates (0.3 microns is the most difficult to filter the size), but its wind resistance is relatively large, generally rarely used in air purifiers, the actual air purifier manufacturers claim that HEPA is not really HEPA its filtration efficiency is slightly lower than HEPA, wind resistance is relatively low. Both the real HEPA and the advertised HEPA make the ining air fresher and cleaner. The filter absorbs chemical fumes, bacteria, dust particles, and pollen, which are filtered by an air purifier and do not contain these pollutants in the air.
Specifications
Technical parameters of MKJ4000-S1 | |
CADR | 854.8m3/h |
Klebsiella pneumoniae sterilization rate | 100% |
Aspergillus Niger sterilization rate | 100% |
Sterilization rate of Staphylococcus albus | 100% |
Natural bacteria death rate | 97.24% |
H3N2 influenza virus killing rate | 99.99% |
Purification rate of PM0.5 for one pass | 100% (on-site inspection) |
UV leakage intensity (at 30cm around the device) | 0μw/cm2 |
Ozone concentration (5cm from the air outlet) | 0.023mg/m3 |
Air dust mite allergen removal rate | 95.23% |
Ultraviolet radiation intensity (at 1cm) | 30850μw/cm2 |
Dimensions (L×W×H) | 520×380×1090mm |
Input power | Max 124W, 3 levels |
Noise | Max 60dB (A), 3 levels |
Product N. W | 50kg |
Product G. W | 55kg |
Voltage and Frequency | 220V/50Hz |
Technical parameters of MKJ4000-S2 | |
CADR | 1706.4m3/h |
Klebsiella pneumoniae sterilization rate | 100% |
Aspergillus Niger sterilization rate | 100% |
Sterilization rate of Staphylococcus albus | 100% |
Natural bacteria death rate | 99.77% |
H3N2 influenza virus killing rate | 99.99% |
Purification rate of PM0.5 for one pass | 100% (on-site inspection) |
UV leakage intensity (at 30cm around the device) | 0μw/cm2 |
Dimensions (L×W×H) | 700×400×1576mm |
Input power | Max 280W, 3 levels |
Noise | Max 60dB (A), 3 levels |
Product N. W | 89kg |
Product G. W | 103kg |
Voltage and Frequency | 220V/50Hz |
Technical parameters of MKJ4000-S4 | |
Airflow rate | 5000m3/h |
Klebsiella pneumoniae sterilization rate | 100% |
Aspergillus Niger sterilization rate | 100% |
Sterilization rate of Staphylococcus albus | 100% |
Natural bacteria death rate | 99.85% |
H3N2 influenza virus killing rate | 99.99% |
Purification rate of PM0.5 for one pass | 100% (on-site inspection) |
Dimensions (L×W×H) | 800×530×1980mm |
Input power | Max 420W, 3 levels |
Noise | Max 60dB (A), 3 levels |
Product N. W | 180 kg |
Product G. W | 215 kg |
Voltage and Frequency | 220V/50Hz |
Applications
Main applications | Respiratory unit, ICU, Emergency unit, Transplantation unit, CT room, Fever clinic unit, Blood wards, Burn wards, Neonatal rooms |
Environment Class I | Laminar flow operation room/ward |
Environment Class II | ICU/Hematological/Burn/Bone Marrow Transplant/Obstetric and Gynecologic/Catheter/Neonatal/Organ Transplant room/ward |
Environment Class III | General/Pediatric/Rooming-in/Gynecologic examination/Treatment/Injection/Dressing/Blood Transfusion/Hemodialysis center/Emergency/Laboratory/Infectious Diseases room/ward |
Public places | The bank, Kindergarten, Movie theaters, fitness halls, clubs, massage rooms, bars, cafes etc |
Home care | Care home such as Asthma, Rhinitis, Dust mites, and Pollen allergies populations/ People with weakened immunity such as major postoperative, hemopathy, Chemoradiotherapy patient/ People suffering from respiratory diseases (Asthma, COPD)/ People with allergies (Pollen allergy, allergic rhinitis, allergic dermatitis)/ Gestational woman, children, the aged etc |
Ekeair ® Mobile air sterilization station
High-efficiency Particulate Air Filter (HEPA) is one of the most popular technologies used in air purification. Standard HEPA filter can absorb 99.7% size of 0.3 microns of suspended particulates (0.3 microns is the most difficult to filter the size), but its wind resistance is relatively large, generally rarely used in air purifiers, the actual air purifier manufacturers claim that HEPA is not really HEPA its filtration efficiency is slightly lower than HEPA, wind resistance is relatively low. Both the real HEPA and the advertised HEPA make the ining air fresher and cleaner. The filter absorbs chemical fumes, bacteria, dust particles, and pollen, which are filtered by an air purifier and do not contain these pollutants in the air.