Mobile Air Purifier With UVC Light , Air Sterilization Mobile Air Purifier
Contact Person : Seline Zheng
Phone Number : +86 573 8188 3938
Minimum Order Quantity : | negotiable | Price : | negotiable |
---|---|---|---|
Packaging Details : | Ekeair Carton boxes with wooden cases | Delivery Time : | 30 days |
Payment Terms : | L/C, T/T | Supply Ability : | 100 sets monthly |
Place of Origin: | China | Brand Name: | Ekeair |
---|---|---|---|
Certification: | CE | Model Number: | MKJ4000-S1 |
Detail Information |
|||
Product Name: | 1000m3MKJ4000-S1 Mobile Hospital Department Uses Molecular Sieve Technology | Purification Area: | ≤50m3/100m3 |
---|---|---|---|
Classification Of Environment: | Indoor ACH≥20/10 Times/h | Eliminating Rates: | 97.24%-100% |
Air Capacity: | 1000 M3/h | QC Profile: | CE LVD EMC |
Size: | 800 Mm (L) × 530 (W) ×980 Mm (H) | Power: | 124W |
Voltage: | 220V | ||
High Light: | 1000m3 Hospital Grade Air Purifier,Molecular Sieve Hospital Grade Air Purifier |
Product Description
1000m3MKJ4000-S1 mobile hospital department uses molecular sieve technology
Description
Ekeair ® Mobile air sterilization station
High-efficiency Particulate Air Filter (HEPA) is one of the most popular technologies used in air purification. Standard HEPA filter can absorb 99.7% size of 0.3 microns of suspended particulates (0.3 microns is the most difficult to filter the size), but its wind resistance is relatively large, generally rarely used in air purifiers, the actual air purifier manufacturers claim that HEPA is not really HEPA its filtration efficiency is slightly lower than HEPA, wind resistance is relatively low. Both the real HEPA and the advertised HEPA make the ining air fresher and cleaner. The filter absorbs chemical fumes, bacteria, dust particles, and pollen, which are filtered by an air purifier and do not contain these pollutants in the air.
Competitive Advantage
· Medical grade HEPA filtration combined with UVC lights
· Removes 100% of white staphylococcus, Aspergillus Niger
· Removes 100% of particles PM0.5
· Large CADR up to 854.8 m3/h (502 CFM)
· Applicable room volume 100 m3 / 3531 ft3 at 10 ACH
· Low Noise max 60 dB with low operating Power max 124W
· 30850μw/cm2 Ultraviolet radiation intensity (at 1cm) with zero leakage
· Human-machine coexistence, No harm and safety to human health
· Easy to move and more effective comparing to Laminar flow or HVAC system’s HEPA
Specifications
Technical parameters of MKJ4000-S1 | |
CADR | 854.8m3/h |
Klebsiella pneumoniae sterilization rate | 100% |
Aspergillus Niger sterilization rate | 100% |
Sterilization rate of Staphylococcus albus | 100% |
Natural bacteria death rate | 97.24% |
H3N2 influenza virus killing rate | 99.99% |
Purification rate of PM0.5 for one pass | 100% (on-site inspection) |
UV leakage intensity (at 30cm around the device) | 0μw/cm2 |
Ozone concentration (5cm from the air outlet) | 0.023mg/m3 |
Air dust mite allergen removal rate | 95.23% |
Ultraviolet radiation intensity (at 1cm) | 30850μw/cm2 |
Dimensions (L×W×H) | 520×380×1090mm |
Input power | Max 124W, 3 levels |
Noise | Max 60dB (A), 3 levels |
Product N. W | 50kg |
Product G. W | 55kg |
Voltage and Frequency | 220V/50Hz |
Classification of Environment | MKJ4000-S1 |
Environment Class II (Indoor ACH≥20 times/h) | ≤50m3 |
Environment Class III (Indoor ACH≥10 times/h) | ≤100 m3 |