Pseudomonas Aeruginosa Air Purifier For Large Living Room

Minimum Order Quantity : negotiable Price : negotiable
Packaging Details : Ekeair Carton boxes with wooden cases Delivery Time : 30 days
Payment Terms : L/C, T/T Supply Ability : 100 sets monthly
Place of Origin: China Brand Name: Ekeair
Certification: CE Model Number: MKJ4000-S1

Detail Information

Product Name: Burn Department Air Purifier Air Capacity: 1000 M3/h
Eliminating Rates: 97.24%-100% Classification Of Environment: Indoor ACH≥20/10 Times/h
Collection Efficiency: Removes 99.99% Of PM0.3 Control System: Wind Capacities Adjustable
QC Profile: CE LVD EMC Size: 800 Mm (L) × 530 (W) ×980 Mm (H)
Purification Area: ≤50m3/100m3 Power: 124W
Voltage: 220V Mesh Type: HEPA Filter Net/ Molecular Sieve/ UVC Lights
Noise: Max 60 DB
High Light:

1000m3 h air purifier for large living room

,

Max 60DB air purifier extra large room

,

Max 60DB air purifier for large living room

Product Description

eliminate Pseudomonas aeruginosa Large Room Burn Department Air Purifier
 
Medical air purifiers are professionally used in hospital operating rooms, preparation rooms, ICU/CCU wards, supply sterile rooms, burn wards, infant rooms, premature infants and delivery rooms, postoperative recovery rooms, laboratories; negative pressure wards, fever clinics, Infusion rooms, hospital clean corridors, etc., and any other places that need to remove harmful aerosols in the room and maintain a certain level of cleanliness.
Competitive Advantage:
 
· Medical grade HEPA filtration combined with UVC lights
· Removes 100% of white staphylococcus, Aspergillus Niger
· Removes 100% of particles PM0.5
· Large CADR up to 854.8 m3/h (502 CFM)
· Applicable room volume 100 m3 / 3531 ft3 at 10 ACH
· Low Noise max 60 dB with low operating Power max 124W
· 30850μw/cm2 Ultraviolet radiation intensity (at 1cm) with zero leakage
· Human-machine coexistence, No harm and safety to human health
· Easy to move and more effective comparing to Laminar flow or HVAC system’s HEPA
 
Functional characteristics:
1.95% removal of dust from air
2.99% high efficiency sterilization
3. remove the bad smell from the air
4. high air volume and large capacity product design to ensure the use of the environment to achieve a considerable number of air exchange times, improve air quality
5. large amounts of air vitamins - light negative ions
6. indoor cleanliness monitoring - real-time monitoring and control of indoor air cleanliness through dirt sensing probe
7. temperature and humidity monitoring-through temperature and humidity sensor, real-time display of indoor air temperature and humidity
Adjust indoor humidity 8. optional humidifier
 
Specifications
 

Technical parameters of MKJ4000-S1
CADR 854.8m3/h
Klebsiella pneumoniae sterilization rate 100%
Aspergillus Niger sterilization rate 100%
Sterilization rate of Staphylococcus albus 100%
Natural bacteria death rate 97.24%
H3Ninfluenza virus killing rate 99.99%
Purification rate of PM0.5 for one pass 100% (on-site inspection)
UV leakage intensity (at 30cm around the device) 0μw/cm2
Ozone concentration (5cm from the air outlet) 0.023mg/m3
Air dust mite allergen removal rate 95.23%
Ultraviolet radiation intensity (at 1cm) 30850μw/cm2
Dimensions (L×W×H) 520×380×1090mm
Input power Max 124W, 3 levels
Noise Max 60dB (A), 3 levels
Product N. W 50kg
Product G. W 55kg
Voltage and Frequency 220V/50Hz

 
Applications
 

Main applications Respiratory unit, ICU, Emergency unit, Transplantation unit, CT room, Fever clinic unit, Blood wards, Burn wards, Neonatal rooms
Environment Class I Laminar flow operation room/ward
Environment Class II ICU/Hematological/Burn/Bone Marrow Transplant/Obstetric and Gynecologic/Catheter/Neonatal/Organ Transplant room/ward
Environment Class III General/Pediatric/Rooming-in/Gynecologic examination/Treatment/Injection/Dressing/Blood Transfusion/Hemodialysis center/Emergency/Laboratory/Infectious Diseases room/ward
Public places The bank, Kindergarten, Movie theaters, fitness halls, clubs, massage rooms, bars, cafes etc
Home care Care home such as Asthma, Rhinitis, Dust mites, and Pollen allergies populations/ People with weakened immunity such as major postoperative, hemopathy, Chemoradiotherapy patient/ People suffering from respiratory diseases (Asthma, COPD)/ People with allergies (Pollen allergy, allergic rhinitis, allergic dermatitis)/ Gestational woman, children, the aged etc

 
Description
 
Ekeair ® Mobile air sterilization station
High-efficiency Particulate Air Filter (HEPA) is one of the most popular technologies used in air purification. Standard HEPA filter can absorb 99.7% size of 0.3 microns of suspended particulates (0.3 microns is the most difficult to filter the size), but its wind resistance is relatively large, generally rarely used in air purifiers, the actual air purifier manufacturers claim that HEPA is not really HEPA its filtration efficiency is slightly lower than HEPA, wind resistance is relatively low. Both the real HEPA and the advertised HEPA make the ining air fresher and cleaner. The filter absorbs chemical fumes, bacteria, dust particles, and pollen, which are filtered by an air purifier and do not contain these pollutants in the air.
 
A Hospital-acquired infection (HAI), also known as a nosocomial infection between healthcare personnel and patients in the hospitals. RTI is of highest mortality rate among infections of operation, hemodialysis and UTI. Reducing the risks of infection become more and more important either to improve air quality environment or to save the cost for the hospitals. Ekeair mobile air sterilization not only realizes human-machines coexistence, but also captures 99.99% of bioaerosols as small as 0.3 microns. With medical-grade HEPA filtration, molecular sieve, unique UVC high-energy particles of photoion α-pure clean control system, it also inactivate microorganisms such as bacteria, fungi, virus.
 
Different from most air purifiers on the market, Ekeair mobile air sterilization station accomplishes 100% eliminates Staphylococcus albus, Klebsiella pneumoniae(bacteria), Aspergillus Niger (Fungi), 99.99% eliminates H3N2 influ virus etc. Superior performance of air blower allows large airflow rate 1000 m3/h but with low noise Max 60 dB. The airflow rate is a significant index which indicates an air sterilizer’s air supply capacity. At the same time, Ekeair air sterilization can reach CADR 854.8 m3/h, which is suitable for 16 m2 room at 20 ACH.
 
FAQ
Q: Are you a manufacturer or trading company?
A: Manufacturer.
 
Q: Where is the production base?
A: Tongxiang City of Zhejiang Province. Marketing center located in Xuhui District of Shanghai.
 
Q: What cooperation mode we could consider?
A: OBM service. We are seeking for a strategic agent or distributors in each country.
 
Q: What’s your main products?
A:We are dedicated to three series and five products, which are Ekeair air sterilizer MKJ4000-S1, MKJ4000-S2, MKJ4000-S4, Ekeair air sterilizer MKJ-A1, Ekeair air quality monitor SC01.
 
Q: What is your sole agent policy?
A: An exclusivity agreement would be considered in order to specify trial order number, first and following stage of purchase number, marketing period, sales training before marketing etc.
 
Q: What is your distribution policy?
A: A distribution agreement would be considered in order to specify trial order number and other conditions.
 
Q: What about applications?
A: Ekeair air sterilization is suitable for those with high requirements for air quality, such as inpatient, fever clinic, CT room, Respiratory room etc. Ekeair has played an important role in helping with fighting against Covid-19’s bioaerosol.
 
 
OBM services:

  • Design, Research & Development, Production of Ekeair brand air sterilization
  • Training of sales, technical, aftersales to agents or distributors in each region.
  • Supports of product marketing to agents or distributors in each region.
  • Supports of aftersales to agents or distributors in each region.

You Might Be Into These
Get in touch with us

Enter Your Message

tracy@ekeair.com